Components
Enterovirus Blend Monoclonal Antibodies - (Catalog No. 3321)One 2 mL dropper vial containing mouse monoclonal antibodies against enteroviruses 70 and 71/Coxsackie A16, protein stabilizer and 0.1% sodium azide (preservative). (Enterovirus 70 MAb is IgG, Enterovirus 71 MAb is an IgG1).
Disclaimer
For in vitro Diagnostic UseCE Mark
General description
Diagnostics Kit
Legal Information
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Physical form
Materials Required But Not Provided:
⋅ Acetone, reagent grade; stored in glass
⋅ Distilled water or deionized water
⋅ Sodium hypochlorite solution, 0.05% (1:100 dilution of household bleach)
⋅ Sterile shell vials with 12 mm coverslips containing monolayer of cell line appropriate for growth of enteroviruses
⋅ Tissue culture media such as RPMI or Eagle′s Minimum Essential Medium (EMEM) with fetal bovine serum (FBS) and antibiotics, or equivalent
⋅ Viral transport medium which is non-inhibitory to enterovirus
⋅ 0.1N NaOH
⋅ 0.1N HCl
⋅ Microscope slides, non-fluorescing
⋅ No. 1 cover slips
⋅ Negative and positive control slides
⋅ Mounting Fluid (Catalog No. 5013)
⋅ Enterovirus 70/71 Control Slides (Catalog No. 5066)
⋅ Anti-Mouse IgG:FITC Conjugate (Catalog No. 5008)
⋅ Normal Mouse Antibody (Catalog No. 5014)
⋅ Phosphate buffered saline (PBS, 0.01 M pH 7.1 to 7.4 with 0.085% NaCl and 0.1% sodium azide), (Catalog No. 5087)
⋅ 0.05% Tween 20 / 0.1% Sodium Azide Solution (optional) (Catalog No. 5037)
⋅ Aspirator device with disposable sterile Pasteur pipettes
⋅ Centrifuge capable of 700-950 x g with biohazard buckets and adapters for shell vials
⋅ Fluorescence microscope with appropriate filter combination for FITC (excitation peak = 490 nm, emission peak = 520 nm) with 100x, 200x, 400x magnification (dry objective)
⋅ Forceps
⋅ Humid chamber
⋅ Incubator, 37 * 1* C
⋅ Syringe filter, 0.45 micron
⋅ Ultrasonic water bath
⋅ Vortex mixer or sonicator
Format: Purified
Storage and Stability
When stored at 2-8° C, the Enterovirus 70 and 71/Coxsackie A16 Blend MAb is stable up to the expiration date printed on the label. Do not freeze or expose to elevated temperatures. Discard any remaining reagent after the expiration date.
Warning and Precautions:
* The performance of Light Diagnostics Enterovirus 70 and 71/Coxsackie A16 Blend MAbs has not been determined on direct specimens.
⋅ Sodium azide, present in the reagent, may react with lead and copper plumbing to form potentially explosive metal azides. Upon disposing of solutions that contain sodium azide, flush plumbing with a large volume of water to prevent build-up.
* Handle all specimens and materials coming in contact with them as potentially infectious materials. Decontaminate with 0.05% sodium hypochlorite prior to disposal.
* Avoid contact with Evans blue, if present in any reagent, as it is a poten-tial carcinogen. If skin contact occurs, flush with large volumes of water.
* Do not mouth pipette reagents.
⋅ Do not allow shell vials or slides to dry at any time during the staining procedure.
⋅ Pooling or alternation of any reagent may cause erroneous results.
⋅ Acetone is extremely flammable and harmful if swallowed or inhaled. Keep away from heat, sparks or flame. Avoid breathing vapor. Use adequate ventilation.
⋅ Mounting Fluid (Catalog No. 5013) contains a fluorescence enhancer that may be destructive to mucous membranes. Avoid direct skin or mucous membrane contact. If contact occurs, flush with large volumes of water.
⋅ Slides prepared too early (﹤25% CPE) or too late (>95% CPE) can be difficult to read and can lead to false negatives.
This product has met the following criteria to qualify for the following awards:
 | Sustainable Product Manufacturing | - Made in a facility which runs on >90% renewable energy
|
To find out more about our Sustainability Attributes, click here.